0 Compare
Add products to the comparison using the scales icon and here you can then compare their parameters.
User
0 Basket
Your basket is empty...

Air sampling pumps and accessories

Air sampling pump selection

This table selection guide will help you to select air sampling pump for your application. All below listed pumps are suitable for workplace monitoring, indoor and outdoor applications. All pumps (other batteries etc.) that we have on our werbsites you can see there.

In the appendix below, you will find an overview of certified pumps for explosive atmospheres and for which zones they are suitable.

Particle samplers suitable for using with these pumps you can find there.

Pocket Pump XR5000 Airchek 52 AirLite Universal PCXR Leland Legacy
Sampling pump Pocket Touch XR5000 Airchek 52 AirLite Universal PCXR Leland Legacy
Flowrate (ml/min) 20 to 500 5 to 5000* 5 to 3000* 5 to 3000* 5 to 5000* 5 to 15 (l/min)
Weight (g) 232 454 567 340 964 1049
Compensation (H2O) up to 20" at 500 ml/min up to 10" at 5 l/min / to 50" at 2 l/min up to 25" at 2 l/min up to 20" at 2 l/min up to 40" at 2 l/min up to 12" at 10 l/min
Built-in timer/clock timer timer timer Ne timer clock
Constant flowrate Yes Yes Yes Yes Yes Yes
Programming Yes Yes Ne Ne Yes# Yes
PC communication Yes Ne Ne Ne Ne Yes
Multiple sorbent tube use Yes Yes Yes Yes Yes Ne
Flow fault indication Yes Yes Yes Yes Yes Yes
RFI/EMI protection Yes Yes Yes Yes Yes Yes
ATEX certificate Ne Ne Yes Ne Yes Ne
CE Yes Yes Yes Yes Yes Yes
Atm. pressure correction Ne Ne Ne Ne Ne Yes
Battery type NiMH Liion/alkal. NiMH alkalické NiMH Liion
Battery check Yes Yes Yes Yes Yes Yes
Temperature correction Yes Yes Ne Yes Ne Yes

Sample bags

SKC produced its first sample bag in the late 1970s. The bag was made of Tedlar® film and soon became the classic sample bag for VOCs. Over the last 30 years, SKC Tedlar bags have been the number one choice of professionals for grab air sampling. However, SKC has also introduced newer high-performance materials, which provide new standards of performance for storage stability and background in bag sampling applications.

SKC manufactures its sample bags out of clean top-grade films including SamplePro FlexFilm, (SKC proprietary film), FlexFoil, and FlexFoil PLUS. Seams are strong, evenly sealed, and leak tested.

Maximum capacity (liter) Tedlar with Single PP fitting Tedlar with Dual SS fittings Qty.
0,5 232-02 - 10
1 232-01 231-01 10
3 232-03 231-03 10
5 232-05 231-05 10
8 (Vac-U-Chamber) 231-939 - 10
10 232-10 231-10 10
25 232-25 231-25 5
40 232-50 231-50 5
80 232-75 231-75 5
100 232-100 231-100 3
Replacement septum 232-01-RS 231-9-04 10

Maximum capacity (liter) FlexFilm with Single PP fitting FlexFilm with Dual SS fittings Flexfoil with Single PP fitting Flexfoil with Single SS fittings Qty.
0,5 N/A N/A - - 10
1 N/A N/A 262-01 263-01 10
3 N/A N/A 262-03 263-03 10
5 N/A N/A 262-05 263-05 10
8 N/A - 262-08 - 10
10 N/A N/A 262-10 263-10 10
25 N/A N/A 262-25 263-25 5
40 N/A N/A - - 5
50 - - 262-50 263-50 5
80 N/A N/A - - 5
100 N/A N/A - - 3
Replacement septum 232-01-RS 231-9-04 236-01-RS 233-01-RS 10

Maximumí capacity (liter) FlexFoil Plus with Single PP fitting FlexFoil Plus with Single SS fitting Qty.* FluoroFilm with Single SS fitting FluoroFilm with Single PTFE fitting Qty.*
0,5 - - N/A N/A 5
1 252-01 253-01 10 N/A N/A 5
3 252-03 253-03 10 N/A N/A 5
5 252-05 253-05 10 - - -
8 252-08 - 10 - - -
10 252-10 253-10 10 - - -
25 252-25 253-25 5 - - -
50 252-50 253-50 5 - - -
Replacement septum 236-01-RS 233-01-RS - - 10

N/A - Bags are temporarily unavailable at this time

Particle Size-selective Sampler guide

This table selection guide will help you to select Particle Sampler for inhalable, respirable or thoracic particles. Click on the pictures you can see the page with the required sampler. All samplers (other flowrates, particle size) that we have on our werbsites you can see there.

Pumps suitable for using with these samplers you can find there.

Sampler Classification Flow Rate L /min 50% Cut-point µm Recommended Calibration Device Filter Size mm Unique Features
Sampler Button Button Sampler Inhalable 4 100 Button Sampler Calibration Adapter 25 Low sensitivity to ambient air conditions
Reduces oversampling of very large particles
Hlavice IOM IOM Sampler Inhalable 2 100 IOM Calibration Adapter 25 Complies with MDHS 14/3
Meets US and international standards including the ACGIH sampling criteria for inhalable dust
Hlavice GS-3 GS-3 Cyclone Respirable 2.75
3.7
4.0
3.5
Multi-purpose Calibration Jar 25
37
Overcomes sampling problems reported with Dorr-Oliver
Conductive
AL cyclone SKC Aluminum Cyclone Respirable 2.5
2.8
4.0
3.5
Aluminum Cyclone Calibration Chamber 25
37
Specified in NIOSH 7500 (silica) and NIOSH 0600 (respirable particulates)
Hlavice PPI Parallel Particle Impactor (PPI) Respirable
Respirable
Thoracic
2
8
2
4.0
4.0
10
Multi-purpose Calibration Jar 37-mm collection filter and 9.5-mm impaction substrate Matches collection curve more closely than any other sampler
8 L/min PPI enhances sensitivity of respirable dust measurements
DPM cassette DPM Cassette Sub-micron 1.7
2
< 1.0 Multi-purpose Calibration Jar if used with GS-1 Cyclone 37 mm Integral precision-jeweled impactor
Tamper-evident seal
Low carbon background filters
Hlavice PEM PEM Sampler PM2.5
PM10 (thoracic)
2
4
10
2.5
10
PEM Calibration cap 37 mm Referenced in EPA Method IP-10A for particles in indoor air
Hlavice Sioutas Sioutas Cascade Impactor Fractionates
2.5 µm & above
1.0 - 2.5 µm

0.5 - 1.0 µm
0.25 - 0.5 µm
< 0.25 µm
9 > 2.5
2.5
1.0
0.5
0.25
None required 37 after filter and 25 collection substrate Minimal particle bounce
Chemical or gravimetric analysis
Sample coarse, fine, and ultrafine particles
Hlavice IMPACT IMPACT Single-stage Impactor PM2.5
PM10
PM Coarse
10
10
10
2.5
10
10, 2.5
IMPACT Cal Adapter 47 collection filter and 37 impaction substrate Follows closely EPA reference methods and criteria
Pre-oiled disposable impaction substrate
Hlavice PMI Personal Modular Impactor (PMI) PM2.5
PM10
PM Coarse
3
3
3
2.5
10
10, 2.5
PMI Cal Adapter 37 collection filter and 25 impaction substrates Pre-oiled disposable impaction substrates
Suitable for thoracic TLVs®or environmental PM parameters