0 Compare
Add products to the comparison using the scales icon and here you can then compare their parameters.
User
0 Basket
Your basket is empty...

Xgard Type 2 for hydrogen (H2), 2000 ppm, aluminium body, M20, ATEX

Xgard Type 2 is flameproof toxic and oxygen gas detector. Electrochemical sensors are used to detect a vast range of toxic gases and oxygen.

Your price
on inquiry
Availability: ask us
Product description

Product description

Xgard Type 2

is flameproof toxic and oxygen gas detector. Electrochemical sensors are used to detect a vast range of toxic gases and oxygen.

Main features

  • low cost of ownership
  • easy installation and maintenance, simple replacement of sensors
  • flexible installation options
  • rugged and reliable
  • made from higly durable aluminium with a though polyester coating, spray deflectors and weatherproof caps are available for use in areas subject to regular wash-downs, or offshore environments
  • ATEX certificate

Czech datasheet in pdf for XGARD detector can be found at this link https://www.chromservis.eu/…as-detection.

Parameters

Parameters

Brand: XGARD
Category: Measurement and control / Gas measurement / Fixed detectors

Technical specifications

Dimensions 156 mm x 166 mm x 111 mm
Weight 1 kg
Ingress protection IP 65, IP66 with weatherproof cap
Cable entries 1 x M20
Terminations 0.5 – 2.5 mm2 csa (20–13 awg)
Sensor type electrochemical
Operating temperature –20 až 50 °C
Humidity 0–90% RH
Zero drift < 2% FSD/month
Response time T90 < 10 s for oxygen, T90 < 30 s for toxic gases
Operating voltage 8–30 V
Power requirements max 24 mA
Electrical output 2-wire 4–20 mA
Approvals ATEX Ex II G, EExd IIC T6

Available gases and ranges*

Carbon Monoxide 50, 100, 250, 300, 500, 1000 ppm
Hydrogen 200, 2000 ppm; 2%, 4% vv
Hydrogen Sulphide 5, 10, 20, 25, 50, 100, 200 ppm
Oxygen 25 % vol.

*One detector is for one gas and one range, therefore it's needed to refer to the relevant part number in case of your interest **Other sensors and ranges maybe available, please contact Chromservis s.r.o.

Use

Gas detectedH2

Operating conditions

ATEXATEX
Analogue output4-20 mA
Detection/Operation principleElectrochemical
Product inquiry
Visited (1)