Xgard Type 1 for ethylene oxide (C2H4O), 10 ppm, nylon body, M20, ATEX

Xgard is intrinsically safe toxic and oxygen gas detector. Electrochemical sensors are used to detect a vast range of toxic gases and oxygen.

Your price
on inquiry
Availability: ask us
Product description

Product description

Xgard is intrinsically safe toxic and oxygen gas detector. Electrochemical sensors are used to detect a vast range of toxic gases and oxygen.

Main features

  • low cost of ownership
  • easy installation and maintenance, simple replacement of sensors
  • flexible installation options
  • rugged and reliable
  • made from glass reinforced nylon, spray deflectors and weatherproof caps are available for use in areas subject to regular wash-downs, or offshore environments
  • ATEX certificate

Czech datasheet in pdf for XGARD detector can be found at this link https://www.chromservis.eu/…as-detection.

Parameters

Parameters

Brand: XGARD
Category: Measurement and control / Gas measurement / Fixed detectors

Technical specifications

Dimensions 156 mm x 166 mm x 111 mm
Weight 3.1 kg
Ingress protection IP65, IP66 with weatherproof cap
Cable entries 1 x M20
Terminations 0.5 – 2.5 mm2 csa (20–13 awg)
Sensor type electrochemical
Operating temperature –20 až 50 °C
Humidity 0–90% RH
Zero drift < 2% FSD/month
Response time T90 < 10 s for oxygen, T90 < 30 s for toxic gases
Operating voltage 8–30 V
Power requirements max 24 mA
Electrical output 2-wire 4–20 mA
Approvals ATEX Ex I G, EExia IIC T4

Available gases and ranges*

Ammonia 50, 100, 250, 500, 1000 ppm
Arsine 1 ppm
Bromine 3 ppm
Carbon Monoxide 50, 100, 200, 250, 500, 1000 ppm
Chlorine 3, 5, 10, 20, 50, 100 ppm
Chlorine Dioxide 1 ppm
Diborane 1 ppm
Ethylene Oxide 10, 50, 100 ppm
Fluorine 1 ppm
Germane 2 ppm
Hydrogen 200, 2000 ppm
Hydrogen Chloride 10, 25 ppm
Hydrogen Cyanide 25, 30 ppm
Hydrogen Fluoride 10 ppm
Hydrogen Sulphide 5, 10, 20, 25, 50, 100, 200, 250, 300, 1000 ppm
Nitric oxide 25, 50, 100 ppm
Nitrogen Dioxide 10, 50, 100 ppm
Oxygen 25 % vol.
Ozone 1 ppm
Phosgene 1 ppm
Phospine 1 ppm
Silane 1 ppm
Sulphur Dioxide 10, 20, 50, 100, 250 ppm
Volatile organics 100 ppm

*One detector is for one gas and one range, therefore it's needed to refer to the relevant part number in case of your interest **Other sensors and ranges maybe available, please contact Chromservis s.r.o.

Use

Gas detectedEtylenoxid

Operating conditions

ATEXATEX
Analogue output4-20 mA
Detection/Operation principleElectrochemical
Product inquiry