S975 SevenExcellence pH/Conductivity/Ion/DO KIT SevenExcellence pH/mV, Conductivity, Dissolved Oxygen, Ion meter – the ultimate multiparameter benchtop meter. This triple channel instrument allows you to measure pH/mV, rel.
SevenExcellence pH/mV, Conductivity, Dissolved Oxygen, Ion meter – the ultimate multiparameter benchtop meter. This triple channel instrument allows you to measure pH/mV, rel. mV/ORP, a large variety of conductivity-based measurements (TDS, salinity, resisitivity, conductivity ash) to determine dissolved oxygen in samples either using digital or polarographic technology, and to measure the concentration and activity of ions in solution.
SevenExcellence™ pH/mV, Conductivity, Dissolved Oxygen, Ion ultimative multichannel meter (Instrument with a pH/Ion, a conductivity, and a DO expansion unit, as well as an InLab® Expert Pro-ISM (pH), an InLab® 731-ISM (conductivity) and an InLab® OptiOx (digital DO) sensors, pH buffers, conductivity standards, and zero-oxygen calibration tablets, as well as guides to pH, ion, conductivity, and DO measurements; also includes a uMix magnetic stirrer)
Brand: | SevenExcellence |
Category: | Laboratory instruments and accessories / Apparatus for measuring samples / Multiparameter instruments |
Short description | Professional modular triple-channel instrument for measuring ion concentrations, pH, mV/ORP, rel. mV, conductivity, salinity, TDS, resistivity and conductivity ash |
Cond. resolution | 0.001 μS/cm to 2000 ms/cm, various different units, defined by user |
Cond. accuracy | +/-0.5% |
pH-range | –2.000 to 20.000 |
pH-resolution | variable: 0.001 / 0.01 / 0.1 |
pH-relative accuracy | ±0.002 |
mV-range | –2000 to 2000 |
mV-resolution | variable: 0.1 / 1 |
mV-relative accuracy | ±0.1 |
Temperature range °C | –30.0 to 130.0 |
Temperature resolution °C | 0.1 |
Temperature accuracy °C | ±0.1 |
TDS range | 0.001 mg/L … 1000 g/L |
Resistivity range | 0.01… 100.0 MOhm*cm |
Salinity range | 0.00 … 80.00 psu, ppt |
Display | 7 inch color TFT display |
Concentration range | Ion:0.001 … 999 999 mg/L , ppm ; 0.0001 … 100 mol/L , % ; 0.001 … 100 00 mmol/L |
Conc. accuracy | Ion:+/- 0.5% |
ISFET pH range | 0.000 to 14.000 |
ISFET pH resolution | variable: 0.001 / 0.01 / 0.1 |
ISFET pH relative accuracy | ± 0.05 |
Touch Screen | Capacitive |
Parameter | Descriptor | Value (RDO – digital) | Value (pol DO – analog) |
---|---|---|---|
Dissolved oxygen | Measuring range | 0.000…50 mg/L (ppm) | 0.000…99 mg/L (ppm) |
Display Resolution | 0.001/0.01/0.1/1 | 0.001/0.01/0.1/1 | |
Accuracy | ± 0.1 mg/L from 0…8 | ±0.5% | |
±0.2 mg/L from 8…20 | |||
±10% from 20…50 | |||
Units | mg/L, ppm, % | mg/L, ppm, % | |
DO Saturation | Measuring range | 0.0…500% | 0.0…600% |
Resolution | 0.1 | 0.1 | |
Pressure | Measuring range | 500 to 1100 mbar | 500 to 1100 mbar |
Resolution | 1 | 1 | |
Accuracy | ±0.2% | ±0.2% | |
General | Calibration points | 2 | 2 |
Sensor input | MiniLTW (IP67) | BNC | |
Pressure compensation | automatic / manual | automatic / manual | |
Pressure units | mbar, hPa, mmHg, Atm | mbar, hPa, mmHg, Atm |
Phys. property | MULTI |
Instrument type | Table |