The ppbRAE 3000 is the most advanced handheld volatile organic compound (VOC) on the market. Its Photoionization Detector’s (PID) extended range of 1 ppb to 10,000 ppm makes it an ideal instrument for applications from HazMat/Homeland Security, industrial hygiene, to Indoor Air Quality and military applications.
The ppbRAE 3000 is the most advanced handheld volatile organic compound (VOC) on the market. Its Photoionization Detector’s (PID) extended range of 1 ppb to 10,000 ppm makes it an ideal instrument for applications from HazMat/Homeland Security, industrial hygiene, to Indoor Air Quality and military applications. The RF modem allows real-time data transmissions with a base controller located up to 500 feet (or two-miles with optional RAELink3 portable modem) away from the ppbRAE 3000 detector. A personal computer can be used as the base station for a ppbRAE 3000 system. The standard ProRAE Remote software is capable of monitoring the input of up to 64 remotelylocated monitors like ppbRAE 3000, or AreaRAE, etc.
Gas Monitor | Range | Resolution | Response Time (T90) |
VOCs | 0 to 9999 ppb | 0.1 ppb | < 3 s |
10 to 99 ppm | 0.01 ppm | < 3 s | |
100 to 999 ppm | 0.1 ppm | < 3 s | |
1000 to 9999 ppm | 1 ppm | < 3 s |
Brand: | ppbRAE 3000 |
Category: | Measurement and control / Gas measurement / Portable detectors |
Size | 25.5 cm x 7.6 cm x 6.4 cm (l x w x h) |
Weight | 738 g |
Sensors | PID with standard 10.6 eV or optional 9.8 eV or 11.7 eV lamps |
Battery | Rechargeable, external field-replaceable Li-Ion battery pack, Alkaline battery adapter |
Operating Hours | 16 hours of operation (12 hours with alkaline battery) |
Display | Graphic 4 lines, 28 × 43 mm, with LED backlight for enhanced display readability |
Keypad | 1 operation and 2 programming keys, 1 flashlight on/off |
Alarms | 95 dB (at 30 cm) buzzer and flashing red LED to indicate exceeded preset limits |
EMI/RFI | Highly resistant to EMI/RFI |
Compliant | with EMC Directive 89/336/EEC |
IP Rating | IP67 unit off and without flexible probe, IP65 unit running |
Datalogging | Standard 6 months at one-minute intervals |
Calibration | Two-point or three-point calibration for zero and span |
Calibration memory | 8 calibration gases, alarm limits, span values and calibration dates |
Sampling Pump | Internal, flow rate at 500 ml/min |
Sample distance | from 30 m horizontally and vertically |
Wireless data transmission | built-in RF modem* |
RF Range | Up to 500' (900 MHz, 433 Mhz, 869 MHz), extendable with RAELink3 Repeater to 2 miles |
Approval | ATEX II 1G EEx ia IIC T4 (pending) |
Operating Temperature | –20° to 50° C |
Operating Humidity | 0% to 95% RH (non-condensing) |
Attachments | Durable black rubber boot with belt clip |
*Frequencies:
Detector type | Jednokanálový |
Sampling | Integrované čerpadlo |
Gas detected | VOC |
Certificate | ATEX |
IP | 65 |
Detector power | Akumulátory |
Data logging | Paměť pro ukládání dat |