PC 50 VioLab kit with pH electrode CHS ChemFlex S7, cond.cell CHS CondiLab 22P, standards and access.

Multimeter PC 50 VioLab Bench multimeter pH – mV/ORP – COND – Temperature Large backlight display pH/mV/Conductivity and Temperature parameters simultaneously pH Selectable resolution: 0.1/0.

Your price
on inquiry
Availability: ask us
Product description

Product description

Multimeter PC 50 VioLab Bench multimeter

pH – mV/ORP – COND – Temperature
  • Large backlight display pH/mV/Conductivity and Temperature parameters simultaneously
pH
  • Selectable resolution: 0.1/0.01 pH
  • Automatic calibration up to 3 points with 2 selectable pH-buffer sets (USA and NIST)
  • Manual calibration up to 2 points with user-defined pH-Buffer
  • Stability parameter (Low-Med-High) for high accuracy measurement
Conductivity
  • Automatic calibration from 1 to 5 points between 5 conductivity standard values: 84 µS – 147 uS – 1413 µS – 12.88mS – 111.9 mS
  • Manual calibration at 1 point (User defined)
  • Automatic and manual compensation of temperature with reference value 15…30 °C

PC 50 VioLab DHS complete kit include pH electrode CHS ChemFlex S7, and conductivity cell CHS CondiLab 22P with integrated ATC with 1m cable BNC/Cinch, 1 m S7/BNC cable electrode holder and colored pH buffer solution pH 7 and pH 4, standard calibration solutions 1413 µS and 12,88 mS and 5V/220V AC power supply.

Parameters

Parameters

Brand: CHS
Category: Laboratory instruments and accessories / Apparatus for measuring samples / Multiparameter instruments

pH

Measuring range 0.00…14.00pH
Resolution 0.1/0.01pH
Calibration points 1 or 3
Buffer recognized USA: 1.68 – 4.01 – 7.00 – 10.01 pH; NIST: 1.68 – 4.01 – 6.86 – 9.18 pH; 2 points defined by user
Indication of the Slope and Offset Yes
Criteria of measurement stability Yes
Indication of calibration point Yes
Potencial measuring range ± 1.000 mV
Potencial resolution 1 mV

ORP

Measuring range ± 1.000 mV
Calibration points 1 (475 mV)

Conductivity

Measuring range 0.0…200 – 2000 µS/20.00–200.0 mS
Resolution 0.1/1 µS to 0.01/0.1 mS
Relative accuracy ±2% full scale
Calibration points 1..5
Calibration standards recognized 84µS, 147 uS, 1413µS, 12.88mS, 111.9mS, 1 point user defined
Cell constant selectable 0.1, 1, 10 cm-1
Temperature coefficient 0.00…10.00 %/°C
Refenece temperature 15…30 °C
Indication of calibration standards Yes
Measuring range 0…200 g/l
TDS factor/Accuracy 0,40..1,00/±1% full scale

Temperature

Measuring range 0…100.0°C
Resolution/Accuracy 0.1°C / ±0.5°C
Temperature compensation Automatic/manual 0…100°C

Others

Inputs 2 BNC, 2 RCA-CINCH (ATC)
IP protection IP54
Power supply 5V DC/220 V
Dimensions/weight instrument 160×140×45(H)­mm/380g