Nitrogen generators Mistral Evolution The Mistral-Evolution is optimized to generate Nitrogen of constant purity that is ideal for laboratory applications like LCMS techniques and other inert gas applications.
The Mistral-Evolution is optimized to generate Nitrogen of constant purity that is ideal for laboratory applications like LCMS techniques and other inert gas applications. The pure Nitrogen is produced locally at low pressure and at ambient temperature which is a very much appreciated advantage over high pressure gastanks or liquid Nitrogen. There will be no extra cost anymore for gas-supply, transportation, storage and handling. Moreover, the large quantities of pure Nitrogen used for LCMS require a continuous supply which cannot be provided by gastanks.
The Mistral Evolution uses the pressure swing adsorption (PSA) technology which removes oxygen, carbon dioxide and water from compressed air and delivers a continuous flow of pure nitrogen of high purity. The first stage of the internal oil-free compressor delivers filtered compressed air to a first set of cartridges with Carbon Molecular Sieve (CMS) which pores removes oxygen, water vapour, carbon dioxide, and hydrocarbons. At the same time a second set of CMS works in regeneration mode with purified nitrogen. Both sets alternate between purification and regeneration modes, ensuring a continuous supply of nitrogen at the specified purity levels. This cycle operates on a continuous basis, ensuring a constant stream of nitrogen gas, 24/7 if required. Carbon Molecular Sieve (CMS) is not considered to be a regular replacement component and is expected to have a minimum service life of at least 10 years, under correct operation and maintenance.
The Mistral Evolution Hybrid Nitrogen Generator was specifically designed to meet the flow, purity and pressure requirements of the LCMS of AB SCIEX with appropriate pressures and flows of nitrogen. Besides high-purity nitrogen production, Mistral Evolution Hybrid provides two outlets of dry filtered air for source and exhaust gas of ion source. A static dryer is used to decrease the DewPoint of the air.
Produced gases | Nitrogen, Dry Air |
Max. N2 flowrate | 10 Nl/min at 80 psi |
Max. Source Air Gas flowrate | 25 Nl/min at 100 psi |
Max. Exhaust Air Gas flowrate | 10 Nl/min at 60 psi |
N2 purity | >99.0% |
N2 pressure accuracy | 0.1 bar ± 0.5% |
Air dewpoint | –40°C at operating pressure |
Operating temperature | 15 to 40°C |
Display | Graphic Display, 128×64px |
Voltage | 110V / 60Hz – 230V / 50Hz |
Consumption | 1800 W |
Protection | IP2× |
Background noise | < 60 dB |
N2 outlet connection | Rapid fitting for 6mm OD tube |
Dimensions (WxDxH) | 482×835×641 mm |
Weight | 90 Kg |
Brand: | iHILIC-Fusion(P) |
Category: | Laboratory instruments and accessories / Chromatography / Gas Generators |
Max. flowrate | 10l/min |
Gas generated | N2 |